RELIABLE POWER WHEN IT MATTERS MOST
When the power goes out, Valtra Generators keep your operation running. From livestock buildings and grain drying to workshops and remote sites, they provide dependable backup and off-grid power, combining Finnish-built AGCO Power engines with durability, fuel efficiency, and straightforward operation. From Arctic winters to hot and demanding environments, Valtra Generators are designed to operate in challenging conditions and deliver dependable performance year after year.
Six models from 60 kVA to 250 kVA deliver reliable power wherever you need it.
WHY CHOOSE VALTRA GENERATORS?
THE RESULT IS A GENERATOR THAT DELIVERS:
- High reliability
- Excellent durability
- Efficient fuel consumption
- Long service life
- Trusted performance in demanding conditions
SOLUTIONS FOR EVERY INSTALLATION
Open or sound-attenuated models.
Open models provide a practical solution for sheltered installations and indoor applications.
Sound-attenuated models are designed for outdoor use and come equipped with: integrated acoustic insulation, pre-installed exhaust systems, durable support structures, and weather-resistant construction.
Their compact design also makes transport, positioning, and installation straightforward.
CONTROL OPTIONS TO MATCH YOUR REQUIREMENTS
Manual or Fully Automatic Operation.
Every operation has different power needs. Valtra Generators are available with a choice of control solutions, allowing you to select the level of automation that best suits your application.
FIND THE RIGHT GENERATOR FOR YOUR NEEDS
With models ranging from 60 kVA to 250 kVA, Valtra offers generator solutions suitable for farms, agricultural businesses, workshops, industrial sites, and remote applications.
Whether you need reliable backup power or a primary power source where grid access is limited, there's a Valtra Generator designed to meet your requirements.
| Model | VG60 | VG90 | VG110 | VG150 | VG200 | VG250 |
|---|---|---|---|---|---|---|
| Power Prime (PRP) kVA / kW | 60 / 48 | 90 / 72 | 110 / 88 | 150 / 120 | 205 / 164 | 250 / 200 |
| Power Standby (LTP) kVA / kW | 66 / 53 | 99 / 79 | 121 / 97 | 165 / 132 | 225 / 180 | 275 / 220 |
| Engine model (AGCO POWER) | 33 DTG | 49 DTG | 49 DTAG | 74 DTG | 74 DTAG | 84 WIG |
| Cylinder qty | 3 | 4 | 4 | 6 | 6 | 6 |
| Rev. speed, rpm | 1 500 | 1 500 | 1 500 | 1 500 | 1 500 | 1 500 |
| Generator | ECP322M4B | ECP342S4A | ECP341L4A | ECP342L4A | ECO383S4A | ECO381L4A |
| Power factor, cos φ | 0.8 ind. | 0.8 ind. | 0.8 ind. | 0.8 ind. | 0.8 ind. | 0.8 ind. |
| Electric system voltage, V | 12 VDC | 12 VDC | 12 VDC | 12 VDC | 12 VDC | 12 VDC |
| Generator IP protection rating | IP23 | IP23 | IP23 | IP23 | IP23 | IP23 |
| Aggregate nominal voltage, V | 400 / 230 | 400 / 230 | 400 / 230 | 400 / 230 | 400 / 230 | 400 / 230 |
| Combustion air, m³/min | 5 | 7,5 | 10 | 12,6 | 17 | 15,5 |
| Cooling air, m³/min | 110 | 145 | 174 | 216 | 234 | 300 |
| Opening f. d. cooling air m² | 0.36 | 0.48 | 0.55 | 0.64 | 0.8 | 1.0 |
| Aggregate nominal current, A (PRP) | 87 | 130 | 159 | 218 | 296 | 361 |
| Rated current of the electr. Systems A | 125 | 160 | 250 | 250 | 400 | 400 |
| Main Fuses, A | 100 | 160 | 250 | 250 | 400 | 630 |
| Short circuit current, A, 10 s | > 261 | > 390 | > 477 | > 654 | > 888 | > 1.083 |
| Fuel tank capacity (l) | 200 / 200 | 200 / 300 | 350 / 300 | 350 / 300 | 350 / 300 | 350 / 350 |
| Working hours with full tank at 100% power, (open / weather protected) | 13 / 13 | 8.5 / 13 | 13 / 11.5 | 10 / 8.5 | 7 / 6 | 7 / 7 |
| Fuel consumption @ 100% PRP (l/h) | 14.7 | 23 | 26 | 34 | 48.5 | 49 |
| Noise level, weather protected, dB (Lp (7 m) / Lw) | 66 / 90.9 | 71.4 / 96.3 | 72.7 / 97.6 | 71.1 / 96 | 74.2 / 99.1 | 73.3 / 98.2 |
| Length, open / weather protected (mm) | 2180 / 2310 | 2250 / 2920 | 2650 / 2920 | 2750 / 2920 | 2850 / 2920 | 3220 / 4210 |
| Width, open / weather protected (mm) | 660 / 1120 | 660 / 1150 | 990 / 1150 | 850 / 1150 | 990 / 1150 | 1100 / 1365 |
| Height, open / weather protected (mm) | 1425 / 1950 | 1475 / 2170 | 1625 / 2170 | 1695 / 2170 | 1725 / 2170 | 1780 / 2150 |
| Dry weight, open / weather protected (kg) | 1000 / 1400 | 1300 / 1800 | 1400 / 1900 | 1600 / 2100 | 1700 / 2250 | 2600 / 3070 |
Prime power – PRP (constant power supply with variable electrical loads over an unlimited time) constant according to the ISO standard. Can be used to supply variable electrical loads over an unlimited time. Ten per cent overload capacity for one hour within a 12-hour period.
Emergency power supply – LTP (Limited Time Running Power) (maximum power for a limited time) ISO standard rating blocked. Can be used for supplying variable electrical loads over a limited time. No overload capacity.
Control system
ComAp InteliNano / InteliLite / InteliGen
READY TO MOVE FORWARDS?
REQUEST A QUOTE
If you already know which generator is right for you, click here to request a quote.VALTRA GENERATORS FAQS
Valtra Generators are designed for backup power, emergency power supply, and off-grid applications. They help farms, businesses, and remote sites maintain operations during power interruptions or where mains electricity is unavailable or prohibitively expensive to install.
Valtra Generators are powered by proven AGCO Power engines manufactured in Linnavuori, Finland. These engines are known for their reliability, durability, and efficient performance in demanding applications.
Yes. Sound-attenuated models are specifically designed for outdoor use and include acoustic insulation, integrated exhaust systems, and robust support structures for dependable operation in a range of conditions.
Automatic models are designed to start within seconds of a power failure and automatically switch off once mains power is restored, helping minimise operational disruption.
The right generator depends on your total power requirements, the equipment being powered, and whether the generator will be used as a backup or primary power source. Your local Valtra Dealer can help assess your requirements and recommend the most suitable model.